What Are Open-Loop Boreholes?

Open-Loop Boreholes

What Are Open-Loop Boreholes?

Open-loop boreholes are drilled specifically for ground source heat pump (GSHP) systems that extract groundwater directly from an aquifer, pass it through a heat exchanger to transfer thermal energy, and then discharge the water — either back into the same aquifer through a second borehole or to a suitable surface discharge point.

Why Open-Loop Systems Are Used

Open-loop geothermal boreholes are chosen where groundwater conditions are favorable, since they offer strong thermal performance at a relatively lower capital cost than closed-loop alternatives. Key advantages include:

  • Higher heat transfer efficiency, since water is in direct contact with the heat exchanger rather than through a sealed pipe.
  • Lower installation cost per unit of heating/cooling capacity compared to closed-loop systems.
  • Simpler system design, requiring fewer boreholes for an equivalent thermal load.
  • Well suited to sites with high-yielding, good-quality aquifers.

How Open-Loop Boreholes Are Drilled

  1. Aquifer assessment – A hydrogeological survey confirms sufficient aquifer yield and water quality for sustained extraction and reinjection.
  2. Abstraction borehole drilling – A standard rotary-drilled borehole is sunk to the aquifer, cased, screened, and developed like a conventional water supply well.
  3. Reinjection borehole drilling – A second borehole is drilled at a suitable distance (to avoid thermal short-circuiting) to receive the water after it passes through the heat exchanger.
  4. Pump and heat exchanger installation – A submersible pump is installed in the abstraction borehole, connected via surface pipework to the building's heat pump unit.
  5. Testing and commissioning – Flow rates, temperature differentials, and reinjection performance are tested to confirm the system meets design capacity.

Open-Loop System Components

  • Abstraction (extraction) borehole
  • Reinjection (return) borehole
  • Submersible pump and control panel
  • Plate heat exchanger
  • Building-side heat pump unit

Open-loop systems require regulatory approval for both water abstraction and reinjection, and are generally most viable for larger commercial or institutional buildings with access to a suitable high-yield aquifer.

Found this useful? Share it:

Related Articles

Teko Eng.
Hydrogeological and Geophysical Survey Tasks List
10 Nov, 2026
Teko Eng.
Top 5 Companies That Provide Samsung TV Repair in Nairobi
10 Nov, 2026
Teko Eng.
Step By Step Process, from Inspection to Drilling
10 Nov, 2026

Contact Teko Engineering Ltd Now For Information

Do you need information about our borehole drilling solutions? Call or send us a message now and learn more about what we have to offer.

Call 0791 999 444 →